PATENTED POSITIONER

  • The First Truly Original Geometric Concept in over 15 Years
  • U.S. Patent #6,789,941
  • Simple to Install and Use
  • No “swing L” on floor
  • No ceiling carriage
  • No image rotation – “true angles”
  • Spherical Coverage from Head to Foot
  • Neuro, cardiac and peripheral studies in one pass
  • Maximum clearance to x-ray tube
  • Angled laterals from both sides
  • Safe by Design
  • Unobstructed head access for anesthesia
  • Balanced, force-limited SID and cranio-caudal drives
  • Compact – Fits in a 16´x 20´Room
  • Short installation time
  • Low installation cost

FLAT PANEL DETECTOR

  • Combination Cesium Iodide and Amorphous Silicon
  • Highest DQE of any material in production today
  • High Spatial and Contrast Resolution
  • 1024 x 1024 x 14 bits at up to 30 fps
  • 512 x 512 x 14 bits at up to 60 fps
  • Low Dose in Combination with Pulsed Acquisition
  • Dose Sensitivity as Low as 0.5 µR/frame
  • No Water Cooling or Bias Light Required
  • Cooler, more reliable operation
  • Wide Dynamic Range
  • 2000:1
  • Large Pixel Size
  • 194 Microns
ENHANCED TABLE
  • Optimized for 500 lb. Payload
  • Easy panning with heavy patients
  • Complements Positioner Capabilities
  • 77 inch¯ long travel for full patient coverage
  • 18 inches of¯ cross travel for bilateral brachial approach
  • Convenient During Prep and Procedure
  • Lowest minimum table height for patient loading
  • Slim base with extra room for feet
  • Extended top provides essential foot-end prep space
  • Safe by Design
  • Lowest absorption carbon fiber top
  • Cables handled internally – no tangle on floor
  • Battery-backed locks and lift, standard
GROUNDED ANODE X-RAY TUBE
  • Patent Pending
  • Single high voltage cable
  • Less soft radiation — recoil electrons do not return to anode
  • Same technology as ultra fine detail mammo systems
  • Sharper, Clearer Images
  • No off-focus radiation to blur images
  • Dual wedge filters to minimize blooming
  • Cool, Silent Operation
  • Grounded anode absorbs 30% less heat for same x-ray output as standard 2-cable tube
  • 2400 watt, integrated tube/tank cooler design
  • No fan or circulator noise
  • 1.5 MHU target
  • Compact Package
  • Small integrated tube and collimator enclosure
  • Reduced collisions with table
HIGH OUTPUT GENERATOR
  • The Most Power Available
  • 2000 mA at 80 kV/160 kW
  • Proven 60 Hz Technology
  • Developed by Power EE’s for Power EE’s
  • Resistant to power line fluctuations
  • Same technology used by utility companies
  • Designed Exclusively for Pulsed Exposures
  • Active cable discharge for both fluoro and record
  • Reduces integrated dose rates
  • Superior to High Frequency Designs
  • Eliminates HF complexity, grid pulsing and slow “fall times”
  • Saves thousands spent on “clean, dedicated power systems” needed for HF generators


This device or system is developmental in nature and not yet available for purchase.
 

 